AC/AC LVDT SX12K/W series

LVDT SX12K

Characteristics

  • Very high MTBF (Main Time Between Failure)
  • Low non-linearity error (<0.15% of Full Scale)
  • Very low thermal drift (<150ppm/°C)
  • Protection IP66

LVDT AC/AC Série SX12K/W


Description

The Meggitt (Sensorex) SX12 range is a high performance LVDT series. They are particularly suitable for severe environment applications (high temperature and pressure), and where accuracy and outstanding reliability are needed.

Two different versions of LVDT are available :

  • SX12K

2 meter or 10 meter shielded cable output
Max. operating temperature 200°C (option)
Max. operating pressure 250 bar (option)
Rugged for extreme environments

  • SX12W

6 wire output

Max. operating temperature 200°C (option)
Max. operating pressure 350 bar (option)
Compact, easy to integrate

These sensors are AC/AC. They should be connected to a signal conditioner model SX3120.


 Applications

  • Test benches
  • Special machines
  • Tests on vehicles
  • Automated production lines
Download product data sheet